TNX Nylon Hammer Plugs
TNX Nylon Hammer Plugs
Description
Light duty nylon anchors suitable for permanent fixing to concrete and masonry. Countersunk headed for flush fixing applications. Completely removable.
Materials
Carbon and Alloy Steels Bright Zinc Plated 5 microns
Stainless Steels Grades A2, A4 according to ISO 3506
Dimensions
Size, d | 6 | 8 | 10 | |
Lengths, L | mm | 40 - 120 | 40 - 160 | 60 - 160 |
Performance Data
Recommended Resistance
Size | 6 | 8 | 10 | |
Tensile Resistance | ||||
Concrete C 20/25 | kN | 0.25 | 0.35 | 0.5 |
Solid Masonry | kN | 0.2 | 0.3 | 0.4 |
AAC | kN | 0.04 | 0.05 | 0.07 |
Shear Resistance | ||||
Concrete C 20/25 | kN | 0.25 | 0.35 | 0.5 |
Solid Masonry | kN | 0.2 | 0.3 | 0.4 |
AAC | kN | 0.06 | 0.06 | 0.07 |
Installation information
Size, D | 6 | 8 | 10 | |
Drill hole Size, do | mm | 6 | 8 | 10 |
Drill depth, ho | mm | 45 | 55 | 65 |
Clearance hole, df | mm | 7 | 9 | 11 |
Effective Embedment, hef | mm | 30 | 40 | 50 |
Maximum Fixture Thickness, tfix | mm | L - hef |
* If the substrate has been plastered, then the drill depth must be increased by the corresponding plaster thickness Holes in masonry must be drilled with rotary action only , hammer drilling is not advisable
Installation procedure
Equipment
Drilling machine
Drill bit of correct diameter
Hammer
Air blower or compressed air with nozzle
Person Protection Equipment (PPE) including gloves.
1. Drill clearance holes in the fixture. Countersink the holes if a flush fixing is required.
2. Position the fixture in place.
3. Using the holes in the fixture as a guide, drill holes in the substrate to the required depth. 4. Blow the dust and debris out of the holes.
5. Insert an anchor through the fixture into the hole.
6. Lightly tap with the hammer until the nylon sleeve is flush with the surface of the fixture.
7. Hammer the screw into the sleeve until flush
8. Repeat the process until all anchors have been installed.
The fixture can now be loaded.